Dew Point Calculator

View results · 48.7 °F

Inputs

Temperature unit
Calculate

Relative humidity is the percentage your weather report or hygrometer shows. Results use the Magnus formula over liquid water.

Result

Dew point
Dew point (°C)
9.3 °C
Temperature–dew point spread
19.3 °F
Absolute humidity
8.6 g/m³
Vapor pressure
11.7 hPa
Saturation vapor pressure
23.3 hPa

Comfort (NWS summer guidance): Dry and comfortable

  • Dry and comfortable< 55 °F
  • Becoming sticky, with muggy evenings55 °F – 65 °F
  • Lots of moisture, becoming oppressive≥ 65 °F
γ=ln⁡50100+17.625×20243.04+20≈0.647\gamma=\ln\frac{50}{100}+\frac{17.625\times20}{243.04+20}\approx0.647
Td=243.04×0.64717.625−0.647≈9.3 ∘CT_d=\frac{243.04\times0.647}{17.625-0.647}\approx9.3\,{}^{\circ}\text{C}

About this tool

The dew point is the temperature to which air must be cooled, at constant pressure and moisture content, for water vapor to start condensing into dew, fog or cloud. Unlike relative humidity, which changes as the air warms and cools during the day, the dew point measures the actual amount of moisture in the air. That makes it the better guide to how humid it feels: a dew point above about 65 °F (18 °C) feels oppressive whatever the temperature.

Dew point is used in weather forecasting, to predict fog, frost and condensation on windows, walls and cold pipes, and to set HVAC, painting and drying conditions.

How it works

Choose what you want to calculate. To find the dew point, enter the air temperature and the relative humidity. To find the relative humidity, enter the air temperature and the dew point. You can also find the air temperature at which air with a given dew point reaches a chosen humidity. Switch between °C and °F at any time; the values you entered are converted.

The calculator uses the Magnus formula with the constants a=17.625a = 17.625 and b=243.04 ∘Cb = 243.04\ ^{\circ}\text{C} published by Alduchov and Eskridge (1996). Besides the dew point it shows the spread between temperature and dew point, the vapor pressure, the absolute humidity in grams of water per cubic metre of air and a comfort rating based on National Weather Service guidance.

Td=b γa−γ,γ=ln⁡RH100+a Tb+TT_d=\frac{b\,\gamma}{a-\gamma},\quad\gamma=\ln\frac{\text{RH}}{100}+\frac{a\,T}{b+T}

Example

At an air temperature of 20 °C (68 °F) and 50% relative humidity, γ=ln⁡0.5+17.625×20243.04+20≈0.6470\gamma = \ln 0.5 + \frac{17.625 \times 20}{243.04 + 20} \approx 0.6470, so the dew point is Td=243.04×0.647017.625−0.6470≈9.3 ∘CT_d = \frac{243.04 \times 0.6470}{17.625 - 0.6470} \approx 9.3\ ^{\circ}\text{C} (48.7 °F). A glass of drink colder than about 9 °C will collect condensation.

In the other direction, at 25 °C with a dew point of 15 °C the relative humidity is 100 ea×15b+15−a×25b+25≈54%100\,e^{\frac{a \times 15}{b + 15} - \frac{a \times 25}{b + 25}} \approx 54\%.

Dew point tables

How dew point feels (National Weather Service summer guidance)

How it feelsDew point (°F)Dew point (°C)
Dry and comfortable< 55< 13
Becoming sticky, with muggy evenings55 – 6513 – 18
Lots of moisture, becoming oppressive≥ 65≥ 18

Dew point (°F) by air temperature and relative humidity

Air temperature (°F)20%30%40%50%60%70%80%90%100%
4021118232731343740
50102027323741444750
60192836414650545760
70273745515560646770
80354654606569737780
90445462697479838790
1005263717884889397100

Dew points are rounded to whole degrees and calculated with the Magnus formula (Alduchov and Eskridge, 1996).

Assumptions and limits

The Magnus formula is an approximation for liquid water that is accurate to within about 0.35 °C between −40 °C and 50 °C (−40 °F and 122 °F), so the calculator accepts temperatures in that range. Below 0 °C (32 °F) it gives the dew point over supercooled water; frost forms at the frost point, which is slightly higher. Absolute humidity and vapor pressure assume ordinary air pressure and ideal-gas behavior.

The comfort bands are the general summer guidance used by the National Weather Service; individual comfort also depends on wind, sunshine, clothing and activity.

Frequently asked questions

What is the difference between dew point and relative humidity?

Relative humidity is how much water vapor the air holds compared with the maximum it could hold at its current temperature, so it rises at night and falls in the afternoon even if the moisture stays the same. The dew point depends only on the amount of moisture, which is why meteorologists use it to describe how muggy it feels.

What dew point is comfortable?

According to National Weather Service guidance, a dew point of 55 °F (13 °C) or lower feels dry and comfortable, 55–65 °F (13–18 °C) becomes sticky with muggy evenings, and 65 °F (18 °C) or higher feels oppressive.

Can the dew point be higher than the air temperature?

No. When the air cools to its dew point it is saturated (100% relative humidity) and any further cooling makes water condense. The dew point therefore equals the air temperature at 100% humidity and is lower at any other humidity.

How do I use the dew point to prevent condensation?

Condensation forms on any surface colder than the dew point of the surrounding air. Keep windows, walls, pipes or surfaces you are painting a few degrees above the dew point, either by warming them or by drying the air. Many coating specifications require the surface to be at least 3 °C (5 °F) above the dew point.

What does the temperature–dew point spread tell me?

The smaller the spread, the closer the air is to saturation. A spread of only a few degrees in the evening often means fog or dew overnight, and a large spread means dry air.

Link with your values

Add these parameters to this page’s address to open it with the values filled in, for example to share a calculation or to link to it from an AI assistant. The result is calculated in the browser: the page HTML shows an example for the default values, and the tool sets the data-url-params attribute once the link’s values are applied.

ParameterValueIf omitted
unitsmetric or imperialset by the first measured value
solve_forwhat to calculate: dew_point, humidity, temperature; give the other 2 valuesdefault dew_point
temperature_ctemperature_fAir temperaturenumber; any unit in the name: _c, _f, _kgive 2 of temperature_f, humidity_pct, dew_point_f
humidity_pctRelative humiditypercent: 6.5 means 6.5%; allowed > 0 – 100give 2 of temperature_f, humidity_pct, dew_point_f
dew_point_cdew_point_fDew pointnumber; any unit in the name: _c, _f, _kgive 2 of temperature_f, humidity_pct, dew_point_f

Examples

  • ?temperature_f=86&humidity_pct=65
  • ?solve_for=humidity&temperature_c=25&dew_point_c=15
  • ?dew_point_f=60&humidity_pct=70

Write decimals with a point. Encode a space as %20, + as %2B, # as %23 and & as %26.

Result elements: [data-result-block="dew-point"]